View Issue Details [ Jump to Notes ] | [ Print ] | ||||||||
ID | Project | Category | View Status | Date Submitted | Last Update | ||||
0000310 | CMake | public | 2003-10-30 09:55 | 2003-10-30 13:17 | |||||
Reporter | System Admin | ||||||||
Assigned To | Brad King | ||||||||
Priority | urgent | Severity | major | Reproducibility | always | ||||
Status | closed | Resolution | fixed | ||||||
Platform | OS | OS Version | |||||||
Product Version | |||||||||
Target Version | Fixed in Version | ||||||||
Summary | 0000310: CTest sends wrong time to cvs on Windows | ||||||||
Description | There is a problem with strftime on windows and it returns full time zone name. | ||||||||
Tags | No tags attached. | ||||||||
Attached Files | |||||||||
Relationships | |
Relationships |
Notes | |
(0000202) System Admin (reporter) 2003-10-30 10:06 |
/cvsroot/CMake/CMake/Source/cmCTest.cxx,v <-- cmCTest.cxx new revision: 1.61; previous revision: 1.60 Fix in 1.8.2 |
(0000203) Brad King (manager) 2003-10-30 13:17 |
Fix has been merged to 1.8 branch for 1.8.2 release. |